E-Stop

 

Pin No. Description
Pin 1 E-Stop Signal – To be used with MPG E-Stop Signal
Pin 2 E-Stop Signal


 
WARNING: To avoid damage to equipment or hazard to personnel, the system installer should connect the E-Stop button so that pressing the button opens the circuit connected to the E-STOP STATUS terminal on the control. This should disable the axis drives and the spindle drive circuits, which should both be connected to this terminal.
 

Wiring example with one E-Stop button on the machine:

Estop Connections

 

Wiring example with E-Stop button on MPG Pendant and machine:



 

E-Stop optocoupler drive disable example:


 